FLUX Pompen Benelux logo
Back to overview
Flow Meter

FMJ 100/PP/1/F | FKM

Nutating disc flowmeter, for use with drum pumps, made from stainless steel, FKM seal.

Item no.
10-A0400088
Material
Polypropylene

Overview

The FLUX FMJ 100 flowmeter, constructed in accordance with the nutating disc principle, can be used with FLUX drum pumps, for example. The filled quantity can be displayed using the FLUXTRONIC® evaluation electronics. Filling and metering processes for virtually all media can therefore be performed with maximum precision and the greatest possible safety. Polypropylene (PP) version. The O-ring is made out of FKM.

Benefits

  • Not affected by small solids
  • Simple handling
  • Easy to mount on pump
  • Also for media that is not self-lubricating

Technical data

Performance

Max. viscosity
2,500 mPas
Max. medium temperature
65 °C
Measuring principle
nutating disc
flow range < 5 mPas
10 to 100 l/min
mat. measur. chamber
PPS
measurement accuracy
±1 %
measurem. repeatab.
0,00 %
other flow meter
without
max. pressure
4 bar
size flow meter
size 100
type flow meter
FMJ
viscosity min.
1 mPas

Electrical

Protection class
IP 54

Materials and sealing

Seal material
FKM
Material
Polypropylene
material axle
without
material oval wheels
without

Dimensions and weight

Weight
1.19 kg
connection outlet
External thread G 1 1/4"
connection inlet
internal thread G 1 1/4"

Approvals

For use in hazardous areas
No
FDA approval
no
Food approval
no
Ex-marking
without

Other

Accessory type
flowmeter
ambient temp. max.
40 °C
ambient temp min.
-20 °C
usage for
F 400 series
customized product
without
batch process poss.
no
pulses per litre
20
sensor optional
without
sensor standard
1x Reed-Sensor
mx.med.-te.i.haz.-a.
without °C
medium temp. min.
0 °C
version
with evaluation electronic FLUXTRONIC®
Durchfl.-Ber. <5mPas
10-100 l/min