FMC 100/PP/0/F | EPDM
Nutating disc flowmeter, for use with drum pumps, made from polypropylene, EPDM seal.
- Item no.
- 10-A0400005
ATEX
- Material
- Polypropylene
Overview
The FLUX FMC 100 flowmeter, constructed in accordance with the nutating disc principle, is designed for use with FLUX drum pumps. In combination with FLUXTRONIC® evaluation electronics, filling and metering processes for virtually all fluids can be performed with maximum precision and the greatest possible safety. In automatic mode, thanks to the FLUXTRONIC® evaluation electronics and use of a switched-mode amplifier, signals can be issued for control purposes. The motor and/or solenoid valves can therefore be controlled and a whole host of processes can be managed, for example. Polypropylene (PP) version. The O-ring is made out of EPDM.
Benefits
- Not affected by small solids
- Simple handling
- Can be controlled by a PLC
- Can also be used in areas subject to explosion hazards
- Easy to mount on pump
- Batch mode possible
- Also for media that is not self-lubricating
Technical data
Performance
- Max. viscosity
- 2,500 mPas
- Max. medium temperature
- 60 °C
- Measuring principle
- nutating disc
- flow range < 5 mPas
- 10 to 100 l/min
- mat. measur. chamber
- PPS
- measurement accuracy
- ±1 %
- measurem. repeatab.
- ±0,15 %
- other flow meter
- without
- max. pressure
- 4 bar
- size flow meter
- size 100
- type flow meter
- FMC
- viscosity min.
- 1 mPas
Electrical
- Protection class
- IP 54
Materials and sealing
- Seal material
- EPDM
- Material
- Polypropylene
- material axle
- without
- material oval wheels
- without
Dimensions and weight
- Weight
- 1.28 kg
- connection outlet
- External thread G 1 1/4"
- connection inlet
- internal thread G 1 1/4"
Approvals
- Ex marking
- Ex II 2G Ex ia IIB T6 Gb
- For use in hazardous areas
- Yes
- FDA approval
- no
- Food approval
- no
Other
- Accessory type
- flowmeter
- ambient temp. max.
- 40 °C
- ambient temp min.
- -20 °C
- usage for
- F 400 series
- customized product
- without
- batch process poss.
- yes, in conjunction with an interface amplifier
- pulses per litre
- 20
- sensor optional
- without
- sensor standard
- 1x Reed-Sensor
- mx.med.-te.i.haz.-a.
- 40 °C
- medium temp. min.
- 0 °C
- version
- with evaluation electronic FLUXTRONIC®
- Durchfl.-Ber. <5mPas
- 10-100 l/min
Downloads